Packaged System:
- FALCO 300 Catalytic Oxidizer
- Regenerative Blower (10 HP, 3 Phase, Explosion Proof)
- FALCO Vapor Control Valve (VCV) with Filter
- Solberg 3″ Inline Blower Filter
- Stainless Steel Vacuum and Pressure Gauges
- Vacuum Relief Valve
- Recirculation Valve For Flow Adjustment
- Stainless Steel Mounting Rails with Fork Lift Pockets
- Mounting Frames, Factory Piping and Wiring Between FALCO, Blower, and VCV
Build America, Buy America (BABA) Compliant. Suitable for federally funded infrastructure & remediation projects.
Resources:
Documents
- Cut Sheet – PDF
- Flow and Control – PDF
- Major Components (FALCO 300 with Regenerative Blower Package) – PDF
- Process and Instrumentation Diagram (P&ID) – DWG | PDF
- Vapor Control Valve (VCV) Installation Manual – PDF
- Vapor Control Valve (VCV) 3D View – PDF
- FALCO 300 Catalytic Oxidizer with Regenerative Blower Package Site Plan – PDF
- FALCO 300 Catalyst Replacement Procedure – PDF
Calculators
- FALCO 300 Energy Use Calculator
- FALCO 300 Flow Rate & Inlet Pressure Calculator
- Pounds / Kilograms Per Day Hydrocarbons Treated Calculator
Additional Resources
The blower package combines with the FALCO 300 to form an integrated soil vapor extraction and treatment system. Factory assembly minimizes work on site. This unit can be installed and running in less than three hours with one conduit to your breaker box and one connection to the vapor source.
Components are mounted on frames joined by forklift beams. One frame supports the blower, Vapor Control Valve, and accessories. The second frame supports the FALCO 300. This low profile system weighs 1,425 lb. and is 4′ wide, 5′ 7″ long, and 6′ 2″ tall. It fits in a parking space or a full size pickup truck.
Careful assembly of quality components and extensive testing yields a standardized system made to last.
Specifications:
| • | FALCO 300 Catalytic Oxidizer |
| • | Gast 10 hp, three phase, explosion proof, regenerative blower model #R7100R-50 |
| When integrated with the FALCO 300, this 10 hp blower provides the following performance: | |
| 25” H20 vacuum = 292 scfm oxidizer flow | |
| 40” H20 vacuum = 268 scfm oxidizer flow | |
| 70” H20 vacuum = 206 scfm oxidizer flow | |
| • | Vapor Control Valve (VCV) with filter |
| • | Solberg 3″ inline blower filter |
| • | Stainless steel vacuum and pressure gauges |
| • | Vacuum relief valve |
| • | Recirculation valve for flow adjustment |
| • | Stainless steel mounting rails with forklift pockets |
| • | Mounting frames, factory piping and wiring between FALCO, blower and VCV |